Product Summary

The PIOON MZ 1470nm configuration delivers up to 20W at 1470nm, a wavelength selected for its strong water absorption and controlled thermal interaction. It is intended for endovenous laser treatment (EVLT) of varicose veins, Endolifting and soft tissue procedures. Because accurate power control supports consistent linear endovenous energy density (LEED) management, the MZ pairs a built-in laser power meter and automatic calibration with a 520nm green aiming beam for fiber positioning. SMA905 + NFC fiber recognition, an 8.8-inch ultra-wide touchscreen and SmartOS 2.0 complete a workflow built for vein clinics and vascular distributors.

1470nm up to 20WEVLT / EVLARadial fiber compatibleAutomatic power calibration
PIOON MZ 1470nm diode laser unit for endovenous laser treatment
MZ 1470nm diode laser console, 8.8-inch touchscreen and SMA905 + NFC port.

Key Features

1470nm up to 20W

Strong water absorption supports controlled thermal interaction for EVLT, Endolifting and soft tissue procedures.

Power meter built for LEED work

Real-time output monitoring with automatic correction of power deviations supports consistent linear endovenous energy density management.

520nm green aiming beam

High-visibility green contrast helps the operator locate the treatment area and confirm fiber position inside the vein.

NFC fiber identification

The SMA905 port identifies compatible authorized fibers and records usage information; NFC functions can be customized per distributor.

SmartOS 2.0 with 32GB storage

8.8-inch Retina HD-level touchscreen stores approximately 1,000,000 protocols and 500 HD treatment tutorials for repeatable settings.

Technical Specifications

Laser typeMedical diode laser
Wavelength1470nm
Output powerUp to 20W
Power controlBuilt-in power meter with automatic calibration
Aiming beam520nm green
Fiber connectorSMA905 + NFC
Display8.8-inch ultra-wide touchscreen, Retina HD level
Operating systemSmartOS 2.0 (MZ Version)
Internal storage32GB
HousingClassic black ABS+PC
Dimensions290 x 280 x 110 mm
Quality systemISO 13485:2016
Regulatory documentsCE certificate (MDD 93/42/EEC, TUV SUD); FDA 510(k) clearance for medical diode laser in general surgery, plastic surgery and dermatology; CE EMC certificate

Clinical applications, wavelength configurations and regulatory approvals vary by market and product model.

Models and Options

1470nmUp to 20W (this configuration)
1940nmUp to 10W for selected endovenous and minimally invasive applications
980nm + 1470nm30W + 15W simultaneous dual-wavelength configuration
1210nm + 1470nm10W + 10W dual-wavelength configuration

Bare, radial and conical optical fibers are available as procedure-specific accessories.

Materials and Structure

The console uses a classic black ABS+PC housing measuring 290 x 280 x 110 mm. The SMA905 port with NFC module is the single fiber interface, and the integrated power meter sits inside the enclosure so output verification does not require a separate measuring instrument. The 8.8-inch ultra-wide touchscreen and SmartOS 2.0 layout group treatment parameters and operating functions for quick reading during a case.

Applications

  • Vascular surgery: endovenous laser treatment (EVLT) for varicose veins with compatible radial optical fibers.
  • Aesthetic medicine: Endolifting, facial contouring, skin tightening and laser-assisted lipolysis.
  • Soft tissue procedures: incision, excision, ablation and coagulation with suitable fibers or handpieces.
  • Related specialties on the MZ platform: proctology and percutaneous laser disc decompression (PLDD) using procedure-specific conical and radial fibers.

Customization

  • NFC functions can be customized for distributor requirements, supporting accessory management and product differentiation.
  • Wavelength and power configurations can be selected from the MZ platform to match the clinical portfolio of each market.
  • PIOON provides OEM/ODM services, training resources, technical support, marketing materials and regulatory documentation for international distributors.

Case Study: Vascular Distributor and Vein Clinic EVLT Program

A vascular medical equipment distributor and a vein clinic have been running distributor-led introduction and demonstration of PIOON EVLT laser solutions for at least two years, including 1470nm or 1940nm configurations and compatible radial optical fibers. The activity supported product education, device familiarization and communication with vascular professionals, and created opportunities to introduce laser systems, wavelength options and compatible radial fiber solutions to distribution partners.

FAQ

What makes 1470nm suitable for EVLT?

1470nm offers strong water absorption, which supports controlled thermal interaction, and the configuration delivers up to 20W for endovenous laser treatment, Endolifting and soft tissue procedures.

How does the system support LEED management?

The built-in power meter monitors actual output and automatically corrects deviations from the selected power setting, which supports consistent linear endovenous energy density management.

Are radial fibers available for vein treatment?

Yes. PIOON provides compatible optical fibers including radial fibers for EVLT, together with specialized handpieces and procedure-specific accessories.

What does the NFC fiber port do?

The SMA905 + NFC interface supports identification of compatible authorized fibers and recording of fiber usage information, and the NFC functions can be customized for distributors.

Can we start with 1470nm and add other wavelengths later?

1470nm 20W, 1940nm 10W, 980nm + 1470nm 30W + 15W and 1210nm + 1470nm 10W + 10W are offered as configurations on the same platform, so distributors can address several clinical markets with one laser platform.

Which certificates are available for registration?

ISO 13485:2016 quality management system certification, CE certificate under MDD 93/42/EEC issued by TUV SUD, FDA 510(k) clearance for medical diode laser in general surgery, plastic surgery and dermatology, and a CE EMC certificate. Approvals vary by market and product model.

How do we request a demonstration unit or quotation?

Contact the PIOON sales team with your market and planned EVLT workflow; the team will confirm configuration, fibers and documentation.

Inquiry Information

Wuhan Pioon Technology Co., Ltd. | Email: sales@pioon.com | WhatsApp: +86 18971249550 | Tel: +86 27 87001110
Address: 12th Floor, Building 1, Innovative Unit, R&D Center Project, Marine World Shipbuilding Park, No. 16, Fozuling 3rd Road, East Lake High-tech Development Zone, 430205, Wuhan, Hubei, China

Request EVLT configuration details

Image Filenames and Alt Text Suggestions

  • pioon-mz-1470nm-evlt-diode-laser.png - Alt: PIOON MZ 1470nm diode laser unit for endovenous laser treatment
  • pioon-mz-surgical-laser-front-panel.jpg - Alt: MZ surgical diode laser front panel with 8.8-inch touchscreen
  • pioon-mz-medical-laser-machine-side.jpg - Alt: MZ medical laser machine housing in classic black ABS+PC
SEO Title1470nm 20W Endovenous Diode Laser for EVLT and Soft Tissue Treatment
Meta DescriptionPIOON MZ 1470nm 20W diode laser for EVLT and endovenous treatment with built-in power meter, automatic calibration, 520nm green aiming beam and NFC fiber recognition.
URL Slug/1470nm-20w-endovenous-diode-laser-evlt
Page H11470nm 20W Endovenous Diode Laser for EVLT and Soft Tissue Treatment